| Specifications |
|
|
|
|
| |
|
Outdoor |
|
Direct Vent |
| |
|
|
|
|
| Natural Gas Model Number |
|
PH2-20ROFN |
|
PH2-20RDVSN |
| LP Gas Model Number |
|
PH2-20ROFP |
|
PH2-20RDVSP |
| Rated Gas Input (BTUs/Hr.) |
|
11,000 (minimum)
150,000 (maximum) Modulating |
|
11,000 (minimum)
150,000 (maximum) Modulating |
| Dimensions (Inches) |
|
13-7/8 (W) x 23-5/8 (H) x 8-7/8 (D) (Outdoor) 13-7/8 (W) x 25-5/8 (H) x 9-7/8 (D)  (Direct Vent) |
| Empty Net Weight (lbs.) |
|
55 |
| Working Water Pressure |
|
14 psi (minimum); 150 psi (maximum) |
| Water Flow Rate |
|
0.44 GPM (minimum) 6.4 GPM (maximum) |
| Gas Connection |
|
3/4" NPT Female (With Supplied Gas Shutoff Valve) |
| Water Connection |
|
3/4" NPT Male |
| Vent Size |
|
N/A (Outdoor Installation) |
|
3"/5" Concentric Category III stainless steel venting required |
| Efficiency Rating |
|
84% |
| Energy Factor |
|
0.82 |
| Electrical Rating |
|
120 VAC / 60 Hz, Less than 2 Amps |
| |
|
|
|
|
| |
|
|
|
|