Specifications |
|
|
|
|
|
|
|
|
|
|
Indoor
|
Outdoor |
|
|
Direct Vent
|
|
|
|
|
|
|
|
Natural Gas Model Number |
|
See: PH2-28RDVSN or PHH-32RDVN
|
|
PH-28C OFN
|
|
See: PH2-28RDVSN or PHH-32RDVN
|
LP Gas Model Number |
|
PH-28C IFSP
|
|
PH-28C OFP
|
|
PH-28C DVSP
|
Safety Engineering |
|
ICAD Safety System
|
|
N/A
|
|
ICAD Safety System
|
|
Heat Exchanger: Film Wrap Overheat Limiter
Flame Failure Safety Monitor: Flame Rod Type
Anti-boil protection
|
Vent Length Maximum |
|
37.5 ft. with 3 elbows
|
|
|
N/A
|
|
37.5 ft. with 3 elbows
|
Rated Gas Input (BTUs/Hr.) |
|
19,000 - 199,900 (modulating)
|
Dimensions (inches) |
|
14-7/8 (W) x 25-3/8 (H) x 11-1/8 (D)
|
Net Weight (lbs.) |
|
55
|
Working Water Pressure |
|
14 psi (minimum); 150 psi (maximum)
|
Minimum Flow for Ingnition |
|
0.66 GPM
|
Gas Connection |
|
3/4" NPT Male
|
Efficiency Rating |
|
84%
|
Energy Factor (DOE) |
|
0.82
|
Electrical Requirement |
|
120 VAC/60 Hz, Less than 2 Amps
|
Freeze Protection |
|
Minus 30 degrees F (including windchill factor)
|
Controller/Diagnostic Display |
|
UMC-117 (included)
|
Multi-Unit System Controller
(sold separately) |
|
2- to 6-unit system: MIC-185 (includes installation box)
7- to 20-unit system: MIC-185 + MICS-180
|
|
|
Factory-set maximum temperature is 120 degrees F |
|
|
For installations above 3,280 feet, the PC board must be adjusted by the high altitude chip. Consult the factory or your supplier for details. |
|